Shieldex EMC RF Enclosures & table Tops
Shieldex RF Enclosure Person Tent Double Layer
Shieldex RF Enclosure Person Tent Triple Layer
Shieldex RF Enclosure Table Top
Shieldex® EMC Enclosure
Our Shieldex® EMC Enclosures are the ideal choice for laboratory tests and measurements in the frequency range from 0.3 GHz to 18 GHz and shield up to 95 dB. Due to their flexible and lightweight components, our shielding enclosures are portable and can be erected and dismantled in a very short time.
Customisable
Whether large or small, we can configure the right tent for you. Our small table tents are suitable for conducting precise measurements on small objects. Large tents can be used to measure bulky objects. Shieldex® EMC Enclosures turn any room into a measuring laboratory.
Shieldex RF Enclosure Table Top | |
![]() |
|
T-Series (RF-X TBZN3S) |
|
Inner size | 610 x 1220 x 610 mm (LxWxH) |
Outer size | 752 x 1362 x 732 mm (LxBxH) |
Material – Triple Layer | Shieldex Nora Dell RS CR Shieldex Zell RS Shieldex Berlin RS |
Clean Room | Clean room compatible to A300 (Class 1000) |
Shielding Effectiveness | Average 80 dB between 0.3 and 18 GHz |
Included | Cable Sleeve, Door, Floor, Alu Frame Transportation Bag, repair Kit, tool, Installation Manual |
Optional | I/O Panel |
Compliance and certification | DIN EN ISO 9001:2015, REACH, RoHS |
Shieldex RF Enclosure – Person Tent | |
![]() |
|
P-Series – Tripple Layer (RF–X PBZN3) |
|
Inner size | 2150 x 2150 x 2180 mm (LxWxH) |
Outer size | 2390 x 2390 x 2300 mm (LxHxW) |
Material | Shieldex Nora Dell RS CR Shieldex Zell RS Shieldex Berlin RS |
Clean Room | Clean room compatible to A300 (Class 1000) |
Shielding Effectiveness | Average 95 dB between 0.3 and 18 GHz |
Included | Cable Sleeve, Door, Alu Frame, repair Kit, Installation Manual |
Optional | I/O Panel, Ventilation System, Window, Floor, Safety Ligthing, Transportation Box |
Compliance and certification | DIN EN ISO 9001:2015, REACH, RoHS |
P-Series -Double Layer (RF–X PBN2) | |
Inner size | 2150 x 2150 x 2180 mm (LxWxH) |
Outer size | 2390 x 2390 x 2300 mm (LxHxW) |
Material | Shieldex Nora Dell RS CR Shieldex Berlin RS |
Clean Room | Clean room compatible to A300 (Class 1000) |
Shielding Effectiveness | Average 85 dB between 0.3 and 18 Ghz |
Included | Cable Sleeve, Door, Alu Frame, repair Kit, Installation Manual |
Optional | I/O Panel, Ventilatioin System, Window, Floor, Safety Ligthing, Transportastion Box |
Compliance and certification | DIN EN ISO 9001:2015, REACH, RoHS |
Plated materials open unlimited opportunities for product development and with over 40 years of experiencee Shieldex supports your ideas with a multitude of plated textile materials and processes. Due to our unique metallization process, our long living premiom EMC fabrics are robust, wash- and durabble, resistant to abrasion and have increased EMC Shielding.
Shieldex® EMC Fabrics | |||
Image | Fabric Name | Common Appications | Specifications |
![]() |
Berlin | Cable Shielding Shielding Enclosure |
Type Fabrics Woven Material 100 % Polyamide / Nylon 6.6 Electrical Surface Resistivity < 0.3 Ω/□ (max. < 0.5 Ω/□) Shielding Effectiveness (0,2–2 GHz) Average of < 62 dB from 0.2 GHz – 2 GHz Shielding Effectiveness (2–5 GHz) Average of < 60 dB from 2 GHz – 5 GHz Shielding Effectiveness (5–14 GHz) Average of < 65 dB from 5 GHz – 14 GHz Weight 58 g/m² ± 10 % Thickness 0.10 mm ± 12 % |
![]() |
Bremen | Electrosensibility selective plating Shielding Enclosure |
Type Fabrics: Woven Material 100 % Polyamide / Nylon 6.6 Electrical Surface Resistivity < 0.3 Ω/□ Shielding Effectiveness (0,2–2 GHz) Average of < 60 dB from 0.2 GHz – 2 GHz Shielding Effectiveness (2–5 GHz) Average of < 60 dB from 2 GHz – 5 GHz Shielding Effectiveness (5–14 GHz) Average of < 62 dB from 5 GHz – 14 GHz Weight 43 g/m² ± 10 % Thickness 0.09 mm ± 12 % |
![]() |
Kassel | Cable Shielding | Type Fabrics: Woven Material 100 % Polyamide / Nylon 6.6 Electrical Surface Resistivity ≤ 0.03 Ω/□ Shielding Effectiveness (0,2–2 GHz) Average of < 88 dB from 0.2 GHz – 2 GHz Shielding Effectiveness (2–5 GHz) Average of < 75 dB from 2 GHz – 5 GHz Shielding Effectiveness (5–14 GHz) Average of < 70 dB from 5 GHz – 14 GHz Weight 85 g/m² ± 12 % Thickness 0.11 mm ± 10 % |
![]() |
Kiel+30 | Cable Shielding | Type Fabrics: Non-Woven Material 100 % Polyamide / Nylon 6.6 Electrical Surface Resistivity < 0.02 Ω/□ Shielding Effectiveness (0,2–2 GHz) Average of < 107 dB from 0.2 GHz – 2 GHz Shielding Effectiveness (2–5 GHz) Average of < 85 dB from 2 GHz – 5 GHz Shielding Effectiveness (5–14 GHz) Average of < 71 dB from 5 GHz – 14 GHz Weight 100 g/m² ± 15 % Thickness 0.25 mm ± 0,12 mm |
![]() |
Nora Dell | electromagnetic shielding Shielding Enclosure |
Type Fabrics: Woven Material 100 % Polyamide / Nylon 6.6 Electrical Surface Resistivity < 0.009 Ω/□ Shielding Effectiveness (0,2–2 GHz) Average of < 87 dB from 0.2 GHz – 2 GHz Shielding Effectiveness (2–5 GHz) Average of < 80 dB from 2 GHz – 5 GHz Shielding Effectiveness (5–14 GHz) Average of < 77 dB from 5 GHz – 14 GHz Weight 100 g/m² ± 15 % Thickness 0.125 mm ± 15 % |
![]() |
Pisa | electromagnetic shielding Shielding Enclosure |
Type Fabrics: Woven Material 100 % Polyester Electrical Surface Resistivity ≤ 0.05 Ω/□ Shielding Effectiveness (0,2–2 GHz) Average of < 71 dB from 0.2 GHz – 2 GHz Shielding Effectiveness (2–5 GHz) Average of < 80 dB from 2 GHz – 5 GHz Shielding Effectiveness (5–14 GHz) Average of < 84 dB from 5 GHz – 14 GHz Shielding Effectiveness (14–26 GHz) Average of < 88 dB from 14 GHz – 26 GHz Weight 80 g/m² ± 10 % Thickness 0.09mm ± 12 % |
![]() |
Porto RS | electromagnetic shielding Shielding Enclosure |
Type Fabrics: Woven Material 100 % Polyester Electrical Surface Resistivity ≤ 0.02 Ω/□ Shielding Effectiveness (0,2–2 GHz) Average of < 91 dB from 0.2 GHz – 2 GHz Shielding Effectiveness (2–5 GHz) Average of < 86 dB from 2 GHz – 5 GHz Shielding Effectiveness (5–14 GHz) Average of < 87 dB from 5 GHz – 14 GHz Shielding Effectiveness (14–26 GHz) Average of < 87 dB from 14 GHz – 26 GHz Weight 120 g/m² ± 10 % Thickness 0.10 mm ± 12 % |
`![]() |
Zell | electromagnetic shielding Shielding Enclosure |
Type Fabrics: Woven Material 100 % Polyamide / Nylon 6.6 Electrical Surface Resistivity < 0.02 Ω/□ Shielding Effectiveness (0,2–2 GHz) Average of < 84 dB from 0.2 GHz – 2 GHz Shielding Effectiveness (2–5 GHz) Average of < 72 dB from 2 GHz – 5 GHz Shielding Effectiveness (5–14 GHz) Average of < 67 dB from 5 GHz – 14 GHz Weight 77 g/m² ± 15 % Thickness 0.11 mm ± 15 % |
![]() |
Zeven 30+ | electromagnetic shielding | Type Fabrics: Non-Woven Material 100 % Polyamide / Nylon 6.6 Electrical Surface Resistivity < 0.02 Ω/□ Shielding Effectiveness (0,2–2 GHz) Average of < 101 dB from 0.2 GHz – 2 GHz Shielding Effectiveness (2–5 GHz) Average of < 83 dB from 2 GHz – 5 GHz Shielding Effectiveness (5–14 GHz) Average of < 73 dB from 5 GHz – 14 GHz Weight 105 g/m² ± 20 % Thickness 0.32 mm ± 20 % |
*A versions include extra interfaces (LAN, RS232), 1 mV/1 mA high res option, 4 lines Trigger In & Out option and On-line Monitoring and Analysis option. Non A models can be upgraded with these options.
Shieldex® shielding curtains
The constant digitalisation process and further development of wireless networks is leading to a growing number of signals being overlaid on top of each other. Signals are disrupted and error messages are becoming more frequent. The Shieldex® shielding curtains offer a solution by guaranteeing controlled wireless communication.
![]() |
![]() |
![]() |
Shieldex® Shielding pouches
Our private data should remain private. Whether laptops, credit cards, health insurance cards or mobile phones – we have developed Shieldex® shielding pouches to prevent data misuse.
Function
The Shieldex® shielding pouches prevent outsiders from accessing your personal data. The shielding pouches can be worn flexibly on the body and can also be attached to the belt if desired. The Shieldex® shielding pouches shield the devices inside from the outside world, so that any communication and resulting data manipulation is prevented.
Shieldex EMC Shielding Components
![]() |
![]() |
![]() |
Shieldex® Zipper S60
Our zip fastenings are completely silvered and thus offer electrical conductivity and EMC shielding. They are incorporated as fastenings into EMC tents or clothing, such as smart textiles. |
Shieldex® Monofil Braided Tube
In these braided, especially lightweight sleeves, made out of lexible Polyamide, bundled cables and wires are protected and shielded – simple and effective.
|
Shieldex® VELCRO® Hook and Loop
Similar to the silvered zip fastenings, the Velcro strips metallised with 99.9% pure silver serve as an attachment point in diverse EMC applications.
|
![]() |
![]() |
|
Shieldex® Ultraflex Tape without mask
The copper and tin-plated tape is coated with a conductive adhesive on the underside. It is supplied optionally with or without a peelable mask. The reverse side is equipped with an electrically conductive adhesive. |
Shieldex® Ultraflex Tape with mask The copper and tin-plated tape is coated with a conductive adhesive on the underside. It is supplied optionally with or without a peelable mask. The reverse side is equipped with an electrically conductive adhesive. |