NH Research 9420 series AC Power Source

Programmable AC/DC Source

The 9420 series AC Power Source from NH Research is designed according to the latest development standards. The source is compact, modular and field expandable which is ideal for designing into automated test equipment (ATE) systems. An advanced built-in measurement system further simplifies ATE system design by providing the essential functions of a digital multi-meter, current transducer, power analyzer, and oscilloscope.

HiVAR® technology

The Model 9420 AC Source utilizing HiVAR® technology avoids this VA derating penalty by allowing the source to be specified in true power while providing more than twice the reactive power capability for loads with capacitive or inductive elements

  • Voltage Range – 175/350VRMS, 200/400VDC
  • 7 models – 8kW/21kVA to 96kW/252kVA
  • Unique configuration flexibility provides for single, split, three-phase operation plus full-power DC
  • HiVAR design eliminates derating nominal power due to reactive loads
  • Frequency – 30 to 880Hz
  • High-resolution waveform digitizer & scope display
  • Precision ultra-low current measurements
  • Seamless, constant-power operating envelope
  • Built-in 9” touch-panel user interface for manual control & measurement display
  • Graphical waveform editor for user-defined waveforms
  • High-level line disturbance programming Macros
  • External PC option to host NHR emPower® Test Sequencer
  • Alternate programming in LabVIEW, native SCPI, & other IVI-compliant languages
  • Improved power density results in half the panel height of a traditional AC source

Advantages

  • Operating envelope of 9420 significantly extends the envelope of similarly sized & priced traditional AC sources.
  • HiVAR provides more reactive power per kW
  • Simplifies automated test stand development
    – Software selectable 1, 2, or 3 Phase operation
    – Isolated digital inputs & outputs
    – Built-in SW watchdog & safety limits
  • Software tools to shorten test development time
    – PC-based tools & NI certified drivers
    – NI certified LabVIEW & IVI-C/IVI-COM drivers
    – Optional: Enerchron test sequencer

Benefits

  • Field upgradeable to higher power
  • Fully emulate any utility/grid condition
  • Simulate non-ideal Phase phase angles (A-B & A-C)

Model 9240 AC Power Source Specifications

Model # 9420-8 9420-12 9420-24 9420-36 9420-48 9420-72 9420-96
AC Output Programmability
Phases/Output Channels Single, Split-Phase Single, Split or 3-Phase
Voltage (LR,HR) 10-175, 350VRMS L-N (split-phase limited to 250V max)
Current Limit Set Ranges (per ф) 0-6, 30A (1ф) 0-6, 30A (3ф) 0-12, 60A (3ф) 0-18, 90A (3ф) 0-24, 120A (3ф) 0-36, 180A (3ф) 0-36, 180A (3ф)
Current Limit Set Max (per Source) 0-12, 60A 0-18, 90A 0-36, 180A 0-54, 270A 0-72, 360A 0-108, 540A 0-144, 720A
Power Limit Set, Max (1, Split, 3ф) 8, 8kW 12, 8, 12kW 24, 16, 24kW 36, 24, 36kW 48, 36, 48kW 72, 48, 72kW 96, 64, 96kW
Maximum Reactive Power 21kVA 31.5kVA 63kVA 94.5kVA 126kVA 189kVA 252kVA
DC Output Programmability
Voltage (LR,HR) 10-200, 400VDC (< 800mV RMS Ripple)
Current Limit Set Max (per Source) 0-12, 60A 0-18, 90A 0-36, 180A 0-54, 270A 0-72, 360A 0-108, 540A 0-144, 720A
Power Limit Set Max (per Source) 0-8kW 0-12kW 0-24kW 0-36kW 0-48kW 0-72kW 0-96kW
Physical
Enclosure Chassis Chassis Cabinet Cabinet Cabinet Cabinet (double) Cabinet (double)
Size (HxWxD) 15 3/4 x 19 x 28″/
400 x 483 x 711mm
15 3/4 x 19 x 28″/
400 x 483 x 711mm
46 x 23 x 30″/
1168 x 584 x 762mm
78 x 23 x 30″/
1981 x 584 x 762mm
78 x 23 x 30″/
1981 x 584 x 762mm
78 x 46 x 30″/
1981 x 1168 x 762mm
78 x 46 x 30″/
1981 x 1168 x 762mm
Weight 135lbs/
61kg
140lbs/
64kg
480lbs/
218kg
640lbs/
290kg
780lbs/
353kg
1280lbs/
581kg
1560lbs/
708kg
* The above specifications show typical configurations & subject to change. Contact NH Research, Inc. for further information.